Twelve Panel InstaCube Saliva Drug Test With Alcohol

$10.50 / per test

The 12 Panel InstaCube Oral Drug Test w/ Alcohol is a comprehensive test that offers a high level of accuracy and provides results in less than 5 minutes. The shelf life of this test is 18 months so the ability to buy in bulk and store the rest, is an attractive feature. Probably the biggest advantage of this test is the fact that you can test for 12 substances at one time, eliminating the costs associated with purchasing additional tests. The no mess collection process is perfect for office use, since it doesn’t require any trained individuals to monitor and handle urine specimens. Order you 12 panel InstaCube Saliva Test today to keep your environment safe!

Drug Test Combinations Available

ICO-8124-ALC — ALC / AMP / BAR / BUP / BZO / COC / mAMP / MTD / OPI / OXY / PCP / THC
SKU: ICO-8124-ALC Category:

Description


DIRECTIONS FOR USE


Instruct the donor to not place anything in the mouth including food, drink, gum, and tobacco products for at least 10 minutes prior to collection.

Step 1: Remove the test device from the pouch and use it as soon as quickly as possible.

Step 2: Remove the collector from the sealed pouch. Take out of the collector cap; Insert the sponge into the mouth. Close mouth and move the sponge around for oral fluid collection. Soak sponge in oral fluid and swab the inside of the mouth and tongue. Collect oral fluid for 7 minutes OR until sponge is soft and fully saturated, No hard spots should be felt on the sponge when saturated.

Step 3: Place the test device on a clean and level surface. Remove the collection sponge from the mouth and insert the sponge GENTLY into the screening device, push down until the collector cap sealed with the device tightly. (See illustration 2)

Step 4: Leave test device upright on flat surface and keep upright while test is running. Wait for the colored lines to appear in test results area. Read the results at 10 minutes. Do not interpret results after 15 minutes

Note: Once the collection sponge locks in place, the device is airtight, tamper evident, and ready to be disposed or sent to lab for confirmation (on presumptive positive results)


INTERPRETATION OF RESULTS


Negative Result

NEGATIVE: Two colored bands appear on the membrane. One band appears in the control region (C) and another band appears in the test region (T). Certain lines may appear lighter or thinner than other lines. A line is to be considered a line whether it is faint, light or dark.

*NOTE: The shade of red in the test line region (Drug/T) will vary, but it should be considered negative whenever there is even a faint pink line.

Preliminary Positive Result:

POSITIVE: Only one colored band appears, in the control region (C). No apparent colored band appears in the test region (T).

Invalid Result:

INVALID: Control band fails to appear. Results from any test which has not produced a control band at the specific read time must be discarded. Please review the procedure and repeat with a new test. If the problem persists, discontinue using the kit immediately and contact your local distributor.

  1. The InstaCube Oral Drug Test provides only a qualitative, preliminary analytical result. A secondary analytical method must be used to obtain a confirmed result. Gas chromatography/mass spectrometry (GC/MS) or gas chromatography/tandem mass spectrometry (GC/MS/MS) is the preferred confirmatory method.
  2. There is a possibility that technical or procedural errors, as well as other interfering substances in the oral fluid specimen may cause erroneous results.
  3. A positive test result does not indicate the concentration of drug in the specimen or the route of administration.

STORAGE AND STABILITY


Store as packaged in the sealed pouch at room temperature. The test device is stable through the expiration date printed on the sealed pouch.

The test device must remain in the sealed pouch until use. DO NOT FREEZE. Do not use beyond the expiration date.